68 CONCEPTS

FoundationsNode

One managed compute system; its identity is distinct from the rack containing it.

FoundationsRack / cabinet

A structure that supports equipment and its power, cooling and cable connections.

FoundationsRack unit / RU

A vertical mounting increment of 1.75 inches; rack elevation records where equipment belongs.

FoundationsAsset identity

The verified hostname, serial number, rack and slot that tie a ticket to the intended physical device.

TroubleshootingFault domain

The set of components affected by a shared dependency; compare one device, one rack and wider scope before choosing a cause.

Server hardwareField-replaceable unit

A component designated for service replacement by its manufacturer; replaceability does not imply live-removal permission.

Server hardwareCPU

General-purpose processor executing operating-system and application instructions.

Server hardwareGPU

Processor optimized for highly parallel work; compare expected hardware inventory with driver-visible inventory.

Server hardwareDIMM

A removable memory module on systems that use sockets; not every server uses removable DIMMs.

Server hardwareECC memory

Error-correcting memory can correct some errors and detect others; trends and uncorrectable events need context and escalation.

Server hardwareNVMe

A storage protocol commonly used by PCIe SSDs; a missing namespace or device does not identify which part failed.

Server hardwarePCIe

The peripheral interconnect used by many GPUs, NICs and drives; a path fault can resemble a failed endpoint.

Server hardwareBMC

Baseboard management controller providing hardware management independently of the host OS. Reachability does not prove the host is healthy.

NetworkingOut-of-band management

Management through a path separate from the production OS/data path; it can remain reachable during a host outage.

Server hardwareSystem event log / SEL

Management-controller event history useful for correlating power, fan and temperature symptoms.

Server hardwareRedfish

DMTF standard for management APIs; access and permissible actions remain site-specific.

Server hardwarePOST

Power-on self-test: early firmware checks before the operating system starts.

PowerPSU

Power supply unit converting its input to power used by system electronics. Input loss and internal PSU failure are different diagnoses.

PowerPDU / rack PDU

Power distribution unit; trace labeled outlets and feeds without opening or operating upstream electrical equipment.

PowerA/B power

Separate designed supply paths; two cords provide useful redundancy only when their upstream dependencies and capacity support it.

PowerUPS

Uninterruptible power supply that supports continuity during input disturbances; actual facility design is site-specific.

PowerBusbar

Conductive distribution structure; vendor rack examples use it to deliver power from shelves to trays.

PowerPower shelf

Rack-level assembly containing power supplies; distinct from a compute tray.

SafetyLockout/tagout

Controlled isolation of hazardous energy using the employer energy-control program and trained, authorized personnel.

SafetyESD control

Electrostatic-discharge controls protect electronics during approved handling; they do not make energized electrical work safe.

OperationsMethod of procedure / MOP

Approved steps, prerequisites, responsibilities, rollback and validation for a planned operation.

SafetyEmergency operating procedure / EOP

Site-specific emergency response; follow it rather than improvising around electrical, thermal or liquid hazards.

CoolingCDU

Coolant distribution unit; in liquid-to-liquid designs it manages a technology loop and exchanges heat with a facility loop. Other architectures exist.

CoolingCold plate

Heat-transfer component in contact with a processor that transfers heat into coolant.

CoolingManifold

A supply or return distribution assembly serving multiple liquid paths.

CoolingQuick disconnect / QD

Designed fluid coupling; disconnect only under the platform procedure and required isolation. Quick does not mean consequence-free.

CoolingDelta T

Temperature difference. For a steady single-phase fluid path, heat transfer is approximately Qdot = mdot × cp × delta T: W = (kg/s) × (J/kg/K) × K. Use properties at the relevant conditions; this does not prescribe site limits.

CoolingAirflow path

The intended intake-to-exhaust route; blocked intakes or recirculation can create local thermal problems.

CoolingAir-cooled chiller

Equipment rejecting heat to outdoor air; the term alone does not determine whether server chips use liquid cooling.

NetworkingNIC

Network interface controller linking a host to a network. Physical presence, link and IP reachability are distinct checks.

NetworkingFabric

Interconnected network infrastructure that carries traffic among systems; identify which fabric a ticket concerns.

NetworkingInfiniBand

A high-performance fabric used in CoreWeave environments; the exact Cheyenne fabric remains unverified.

NetworkingRDMA

Remote direct memory access: data transfer between systems with reduced host CPU involvement; a capability, not a connector shape.

NetworkingRoCE

RDMA over Converged Ethernet; do not infer InfiniBand merely because RDMA is in use.

NetworkingNVLink

NVIDIA interconnect used between GPUs and switches in supported systems; separate from the external cluster network.

NetworkingDPU

Data processing unit offloading infrastructure work; model and functions depend on platform.

NetworkingTop-of-rack switch

Switch associated with a rack; its role may be management or data networking, so identify the actual path.

LinuxAdministrative state

Whether an interface is enabled by configuration; IFF_UP is separate from physical carrier.

LinuxCarrier / LOWER_UP

Driver-reported lower-layer link readiness. Missing carrier does not by itself identify cable, optic or port as the cause.

LinuxRoute

Rule selecting a next hop/interface for an IP destination; working link alone does not establish a usable route.

LinuxDNS

Name resolution. Failure to resolve a name differs from failure to reach a numeric IP address.

FiberSingle-mode fiber

Fiber supporting a single propagation mode in its intended operating range; use the transceiver specification to choose compatible media.

FiberMultimode fiber

Fiber supporting multiple modes; reach and compatibility depend on fiber grade and optical standard.

FiberLC connector

Small-form optical connector commonly used in duplex connections; connector shape alone does not identify media compatibility.

FiberMPO / MTP

Multi-fiber connector family; MTP is a branded MPO implementation. Fiber count, keying, polish and polarity must match the design.

FiberOptical transceiver

Module converting electrical and optical signals; match supported type, speed, wavelength, media and reach.

FiberFiber polarity

The end-to-end mapping that connects transmitter channels to intended receiver channels.

FiberDigital optical monitoring / DOM

Transceiver telemetry such as received optical power and temperature where supported; interpret against vendor limits.

FiberDAC / AOC

Direct-attach copper and active optical cable assemblies respectively; follow supported cable and port combinations.

CoreWeave operationsOnboard

Initial physical inspection and certification gate before automated provisioning proceeds.

CoreWeave operationsZap

Firmware preparation stage in CoreWeave Day 1.

CoreWeave operationsSeatrial

Observation stage before the Day 1 Test stage.

CoreWeave operationsReady

Validated inventory eligible for customer delivery.

CoreWeave operationsTriage

Workflow for investigating production problems and deciding the next recovery path.

OperationsRMA

Return merchandise authorization/vendor repair workflow; preserve identifiers and follow data handling policy.

OperationsRevalidation

Evidence that the repaired system meets required health checks before return to service.

GPU diagnosticsXid

NVIDIA driver error identifier: a clue requiring context, not a complete root-cause diagnosis.

TroubleshootingTelemetry

Measured status, counters and events; correlate timestamp, scope and baseline before deciding what a signal means.

OperationsChange control

Confirm authority, affected services, maintenance scope and rollback before a disruptive action.

OperationsTechnical handoff

A concise record of identity, impact, time, observations, actions, validation and unresolved questions.

EvidenceCheyenne evidence boundary

Developer confirms planned first-phase capacity and air-cooled chillers; exact GPU generation, rack layout and fabric are not established.

EvidenceCheyenne GPU generation

Exact installed GPU generation and OEM remain unverified; vendor reference hardware is a learning example.

InterviewSTAR story

Structure a real example as situation, task, your actions and results; add what you learned without inventing metrics.